Load cells
Load cells presently manufactured by AEP transducers are included in the requisites of OIML R60 regulations (International Organization of Legal Metrology) which establishes all the tests (temperature, moisture, barometric pressure, etc…) to be passed by the product in order to be included in certain precision classes C2, C3, C4 …
To ensure these requisites, AEP transducers has developed inside itself some direct-weight automatic equipment which were accredited by ACCREDIA in 1996 for model control according to this regulation.
Load cells are periodically checked by Metrological Laboratory personnel who performs constant tests on series production, with an always careful view to the product continuous improvement.
Thanks to technical staff know-how,all the procedures to perform model approval for legal uses are being activated by autorithies in control.

Showing all 24 results
-

C2S
C2S
Load cell for the measurement of static and dynamic loads in COMPRESSION
Nominal Load from 100 kg to 200 tons
Class (OIML R60) C1, C2 and C3
Combined Error: 0,023%
Output: 2mV/V
On request


-

C2S-AMP
C2S-AMP
Load cell for the measurement of static loads in COMPRESSION.
Nominal Load from 100 kg to 200 tons
linearity andhysteresis 0.03%

-

CBS
CBS
Load cell for the measurement of static and dynamic loads in COMPRESSION.
Nominal Load from 250 kg to 100 tons
Combined Error: 0,03%
Output: 2mV/V
LOW COST version produced for over 30 years

-

UPC
UPC
WEIGHING UNIT for Load Cell model C2S and CBS
Used in weighing tanks, silos and hoppers.
Nominal loads from 100 kg to 100 tons

-

CLS
CLS

Load cell for the measurement of static and dynamic loads in COMPRESSION.
Nominal Load from 30t to 500t
Class (OIML R60) C1 and C2
Combined Error: 0,023%
Output: 2mV/V
-

TS
TS
Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION
Nominal Load from 10 kg to 10 tons
Class (OIML R60) C2, C3 and C4
Combined Error: 0,018%
Output: 2mV/VAlso in version


-

TS-AMP
TS-AMP
Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION
Nominal Load from 10 kg to 10 tons
linearity and hysteresis 0,030%
Standar output M12 connector

-

TCA
TCA
Load cell for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 1 kg to 50 kg
Linearity and Hysteresis 0.03%
Output: 2mV/V
-

TCE
TCE
Load cell for the measurement of static and dynamic loads in COMPRESSION and TENSION
Nominal Load from 350 kg to 20 tons
Linearity and Hysteresis 0.03%
Output: 2mV/Von request



-

TCE-AMP
TCE-AMP
Load cell for the measurement of static loads in COMPRESSION and TENSION
Nominal Load from 350 tons to 20 tons
Linearity and Hysteresis 0.03%
Standar output M12 connector

-

T20
T20
Load cell for the measurement of static and dynamic loads in TENSION
Nominal Load from 5 tons to 20 tons
Class (OIML R60) C2 and C3
Combined Error: 0,019%
Output: 2mV/V
on request


-

T20-AMP
T20-AMP
Load cell for the measurement of static loads in TENSION
Nominal Load from 5 tons to 20 tons
Linearity and Hysteresis 0.03%
Standar output M12 connector

-

D200
D200
Load cell for the measurement of static and dynamic loads in TENSION
Nominal Load from 20 tons to 100 tons
Linearity: 0,10%
Output: 2mV/V
on request

-

CLT
CLT
Load cell for the measurement of static and dynamic loads in TENSION and COMPRESSION
Nominal Load from 100 tons to 250 tons
Linearity: 0,10%
Output: 2mV/V
on request

-

F1
F1
BENDING BAEM load cell for the measurement of static and dynamic loads.
Nominal Load from 2,5 kg to 200 kg
Class (OIML R60) C2 and C3
Combined Error: 0,020%
Output: 2mV/V

-

UPF1
UPF1
WEIGHING UNIT for Load Cell model F1.
Used in weighing tanks, silos and hoppers.
Nominal loads from 2,5 kg to 200 kg
-

F3
F3
BENDING BAEM load cell for the measurement of static and dynamic loads
Nominal Load from 10 kg to 2 tons
Class (OIML R60) C2 and C3
Combined Error: 0,018%
Output: 2mV/V
-

FT1
FT1
SHEAR BEAM load cell for the measurement of static and dynamic loads Nominal Load from 350 kg to 7,5 tons
Class (OIML R60) C2 and C3
Combined Error: 0,020%
Output: 2mV/V

-

FT1-AMP
FT1-AMP

SHEAR BEAM load cell for the measurement of static and dynamic loads
Nominal Load from 350 kg to 2 tons
Linearity and Hysteresis 0.05%

-

UPFT1
UPFT1
WEIGHING UNIT for Load Cell model FT1 Used in weighing tanks, silos and hoppers
Nominal loads from 350 kg to 5 tons
-

FT2
FT2
SHEAR BEAM load cell for the measurement of static and dynamic loads.
Nominal Load from 500 kg to 10 tons
Class (OIML R60) C2 and C3
Combined Error: 0,019%
Output: 2mV/VOn request


-

FT6
FT6
OFF CENTER load cell for the measurement of static and dynamic loads
Nominal Load from 5 kg to 100 kg
Class (OIML R60) C2
Combined Error: 0,028%
Output: 2mV/V

-

FT8P
FT8P

DOUBLE SHEAR BEAM load cell for the measurement of static and dynamic loads
Nominal Load from 10 ton to 20 tons
Linearity and Hysteresis 0.05%
Output: 2mV/V
-

FT9
FT9

DOUBLE SHEAR BEAM load cell for the measurement of static and dynamic.
loads Nominal Load 15 ton
Linearity and Hysteresis 0.10%
Output: 2mV/V